Vue de la page 39
37 ViewSonic PJ510
Regarding The Indicator Lamps
Lighting and flashing of the POWER indicator, the LAMP indicator, and the TEMP indicator have
the meanings as described in the Table below. Please respond in accordance with the instructions
within the Table. If the same indication is displayed after the treatment, or if an indication other than
the following is displayed, please contact your dealer or service company.
ATTENTION
When the interior portion has become overheated, for safety purposes, the power source may be
automatically turned off, and the indicator lamps may also be turned off. In such a case, press the “
” (OFF) side of the power switch, and wait at least 45 minutes. After the unit has sufficiently cooled
down, please make confirmation of the attachment state of the lamp and lamp cover, and then turn the
power on again.
POWER
indicator
LAMP
indicator
TEMP indi-
cator
Description
Lighting in
orange
Turned off
Turned off
The unit is in a standby state. Please refer to the “Power ON/OFF” sec-
tion of this manual.
Flashing in
green
Turned off Turned off
The unit is warming up. Please wait.
Lighting in
green
Turned off Turned off
The unit is in an ON state. Ordinary operations may be performed.
Flashing in
orange
Turned off Turned off
The unit is cooling down. Please wait.
Blinking in
red
--
The unit is cooling down. A certain error has been detected. Wait until
the POWER indicator has finished flashing, and then perform the
proper response measure using the item descriptions below as refer-
ence.
Lighting or
blinking in
red
Lighting in
red
Turned off
The projector lamp has not been properly fixed (attached), the projec-
tor lamp does not light, and/or there is a possibility that the interior por-
tion has become heated. Turn the power OFF and wait at least 20
minutes. After the unit has sufficiently cooled down, please make con-
firmation of the following items, and then turn the power ON again. If
the same indication is displayed, please change the lamp.
• Is there blockage of the air passage aperture?
• Is the air filter is dirty?
• Does the peripheral temperature exceed 35°C?
Lighting or
blinking in
red
Blinking in
red
Turned off
The lamp cover has not been properly fixed (attached). Turn the power
OFF and wait at least 45 minutes. After the unit has sufficiently cooled
down, please make confirmation of the attachment state of the lamp
and lamp cover, and then turn the power ON again.
Vue de la page 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 ... 48 49

Commentaires sur ces manuels

Pas de commentaire